14-apr-11 07:25:00 Measurements ended --- . Number of lamps (L) = 7 . Filter running time = 74.66 hours . Total airflow this filter = 21.91 cubic meters . Mean BC concentration of all lamps = 64 ng/m3 . Report for lamp 1 (370 nm): . Ending voltages: sen(beam) = .506 sen(zero) = 0.021 . ref(beam) = 2.183 ref(zero) = 0.021 . Optical attenuation of filter deposit = 99 . Total aerosol black carbon on filter = 1253 ng Mean aerosol black carbon concentration = 57 ng/m3 --- The reference beam showed lamp intensity fluctuations of 42 ppm. --- Report for lamp 2 (470 nm): . Ending voltages: sen(beam) = .931 sen(zero) = 0.021 . ref(beam) = 2.410 ref(zero) = 0.021 . Optical attenuation of filter deposit = 83 . Total aerosol black carbon on filter = 1349 ng Mean aerosol black carbon concentration = 61 ng/m3 --- The reference beam showed lamp intensity fluctuations of 32 ppm. --- Report for lamp 3 (520 nm): . Ending voltages: sen(beam) = .674 sen(zero) = 0.021 . ref(beam) = 2.484 ref(zero) = 0.021 . Optical attenuation of filter deposit = 75 . Total aerosol black carbon on filter = 1343 ng Mean aerosol black carbon concentration = 61 ng/m3 --- The reference beam showed lamp intensity fluctuations of 31 ppm. --- Report for lamp 4 (590 nm): . Ending voltages: sen(beam) = .961 sen(zero) = 0.021 . ref(beam) = 1.233 ref(zero) = 0.021 . Optical attenuation of filter deposit = 69 . Total aerosol black carbon on filter = 1398 ng Mean aerosol black carbon concentration = 63 ng/m3 --- The reference beam showed lamp intensity fluctuations of 101 ppm. --- Report for lamp 5 (660 nm): . Ending voltages: sen(beam) = 1.373 sen(zero) = 0.021 . ref(beam) = 2.522 ref(zero) = 0.021 . Optical attenuation of filter deposit = 64 . Total aerosol black carbon on filter = 1457 ng Mean aerosol black carbon concentration = 66 ng/m3 --- The reference beam showed lamp intensity fluctuations of 66 ppm. --- Report for lamp 6 (880 nm): . Ending voltages: sen(beam) = 1.400 sen(zero) = 0.021 . ref(beam) = 3.545 ref(zero) = 0.021 . Optical attenuation of filter deposit = 52 . Total aerosol black carbon on filter = 1570 ng Mean aerosol black carbon concentration = 71 ng/m3 --- The reference beam showed lamp intensity fluctuations of 71 ppm. --- Report for lamp 7 (950 nm): . Ending voltages: sen(beam) = 1.144 sen(zero) = 0.021 . ref(beam) = 4.564 ref(zero) = 0.021 . Optical attenuation of filter deposit = 48 . Total aerosol black carbon on filter = 1563 ng Mean aerosol black carbon concentration = 71 ng/m3 --- The reference beam showed lamp intensity fluctuations of 69 ppm. --- Disk space = 2.016256E+07 bytes free: One entry at every 5 minutes. There is space for 4286 hours ( 179 days) more data --- 14-apr-11 07:25:00 Tape feeder mechanism advancing for 1 spot(s). --- ============================================================= --- MAGEE SCIEN. AETHALOMETER --- Aethalometer No. 463 --- 14-apr-11 07:39:54 Measurements started Starting voltages: . sen(zero) = 0.021 ref(zero) = 0.021 . Lamp 1 (370 nm): sen(beam) = 1.290 ref(beam) = 2.173 . Lamp 2 (470 nm): sen(beam) = 2.109 ref(beam) = 2.399 . Lamp 3 (520 nm): sen(beam) = 1.390 ref(beam) = 2.477 . Lamp 4 (590 nm): sen(beam) = 1.853 ref(beam) = 1.219 . Lamp 5 (660 nm): sen(beam) = 2.574 ref(beam) = 2.504 . Lamp 6 (880 nm): sen(beam) = 2.313 ref(beam) = 3.513 . Lamp 7 (950 nm): sen(beam) = 1.809 ref(beam) = 4.525 ---