Astoria, OR

      Site ID:     ast
      Latitude:     46.156900 N
      Longitude:     -123.883000 W
      Elevation:     3 meters
      Active:     Y
      Site Table:     Site Table
      Data:     Realtime Display

Instrument Name     Project Name     Install Date     Data Types
449 MHz Wind Profiler Digital     Hydrometeorology Testbed - West     2015-09-03          view
Radio Acoustic Sounding System     Hydrometeorology Testbed - West     2015-09-10          view
Wind Speed and Direction 5106-5A     Hydrometeorology Testbed - West     2015-09-10          view
GpsTrimble NetR8     Hydrometeorology Testbed - West     2015-09-10          view
Datalogger CR800     Hydrometeorology Testbed - West     2015-09-10          view
Solar Radiation - CMP3     Hydrometeorology Testbed - West     2015-09-10          view
Tipping Bucket TR525USW     Hydrometeorology Testbed - West     2015-09-10          view
Pressure - PTB110B     Hydrometeorology Testbed - West     2015-09-10          view
Temp/RH - HygroVUE 10     Hydrometeorology Testbed - West     2024-02-05          view

Instrument Name     Project Name     Install Date     Removal Date     Data Types
Temp/RH CS215     Hydrometeorology Testbed - West     2015-09-10     2024-02-05          view

  OutageID     SiteID     Failure Type     Start Date      End Date      Description     Resolution Description  
838 ast Power Failure 2022-12-27 05:00:00 2022-12-27 21:00:00 Unable to connect to cellular router; possible power outage Power restored
823 ast Hardware - Instrument 2022-08-21 20:00:00 2022-12-14 03:00:00 Issue with switches or beam steering unit Equipment repaired
769 ast Hardware - Instrument 2021-04-15 21:02:00 2021-07-03 18:54:00 Radar PC unable to connect to datalogger. Datalogger battery voltage was at adequate levels when connectivity was lost; possible data cable issue. Cable repaired during site visit
750 ast Hardware - Instrument 2021-01-05 00:00:00 2021-01-28 00:00:00 Tipping bucket grossly under-reporting precipitation amounts; begin time of malfunction unknown Tipping bucket funnel cleared of debris by on-site airport manager
563 ast Power Failure 2017-11-17 06:30:00 2017-11-20 16:15:00 Planned power outage Power restored on 11/17; System time on UPS reset to 1970 during power cycle, which prevented scheduled power up. NTP time syncing enabled on UPS.
533 ast Communication - Cellular 2017-05-15 09:00:00 2017-05-15 16:00:00 Can't reach cellular router. Either power or router issue. Cellular service issue resolved.