OutageID |
SiteID |
Failure Type |
Start Date |
End Date |
Description |
Resolution Description |
724 |
bbd |
Communication - Cellular |
2020-06-10 13:02:00 |
2021-10-19 18:00:00 |
Unable to connect to cellular modem |
Site removed |
698 |
bbd |
Communication - Cellular |
2020-03-07 13:00:00 |
2020-03-13 18:00:00 |
Can't connect to cellular modem; suspected serial-server crash |
Datalogger OS updated and cellular modem firmware rolled back to version v.2.008 |
689 |
bbd |
Communication - Cellular |
2020-02-06 15:00:00 |
2020-02-10 21:30:00 |
Can't connect to cellular modem |
Modem power source switched from CS/IO port to direct battery connection |
637 |
bbd |
Hardware - Instrument |
2018-06-27 13:18:00 |
2019-07-19 02:52:00 |
Datalogger battery failure; 9-volt reading prior to outage |
The CGFI power switch had tripped at the power box. Reset and installed new battery in the data logger. 7-18-2019
|
520 |
bbd |
Communication - Cellular |
2017-03-08 12:00:00 |
2017-03-08 16:00:00 |
Datalogger unreachable. |
Communications restored. |
528 |
bbd |
Hardware - Instrument |
2017-02-24 00:00:00 |
2017-06-20 18:00:00 |
Heated tipping bucket precipitation gauge malfunction. |
Tipping bucket replaced. |
468 |
bbd |
Hardware - Instrument |
2015-10-05 12:00:00 |
2015-10-20 00:00:00 |
The datalogger will not run a program. Tried sending a program via logger net remotely and keypad but does not run. Datalogger should be replaced. |
Datalogger replaced. |
448 |
bbd |
Hardware - Instrument |
2015-04-23 05:00:00 |
2015-04-27 16:00:00 |
Unable to talk to datalogger via PC. Could be damaged to lighting in the area. |
RAD modem was damaged. Replaced. |
438 |
bbd |
Hardware - Instrument |
2015-02-01 00:00:00 |
2015-03-10 00:00:00 |
The 10cm and 15cm probes are reporting invalid data. Disabled for display. |
soil probes fixed. |
376 |
bbd |
Hardware - Instrument |
2014-04-07 00:00:00 |
2014-05-01 00:00:00 |
Net Radiation dome broke. Removed from display until fixed.
|
dome replaced. |
374 |
bbd |
Hardware - Instrument |
2014-03-30 00:00:00 |
2014-05-01 00:00:00 |
PC needs to replaced. Powered off. |
Powered down for season. Will replace next season. |
298 |
bbd |
Hardware - PC |
2013-01-13 19:00:00 |
2013-04-16 18:00:00 |
Datalogger service stops and hangs intermittently after running for several hours. Investigating causes. Update. 3/4/13. New Service installed but still failing. Computer was scheduled to be replaced but new computer was damaged during shipping. |
Datalogger changed to CR10x. |
285 |
bbd |
Hardware - Instrument |
2012-12-14 16:00:00 |
2013-01-07 23:00:00 |
Snow depth sensor failed. |
Snow depth sensor replaced. |
276 |
bbd |
Power Failure |
2012-12-02 15:00:00 |
2012-12-02 19:00:00 |
Modem unresponsive. Could be a power failure, modem issue, phone line issue, or comms computer issue. |
Comms restored. Power outage likely. |
269 |
bbd |
Communication - Phone |
2012-10-15 16:00:00 |
2012-11-30 21:00:00 |
Modem not answering. Could be power or comms modem issue.
Update 10/18/12. Phone line taken down due to construction in the area. Will replace with cellular modem on next visit. Data collecting locally. |
Replaced modem with Cellular router. |
160 |
bbd |
Communication - Phone |
2011-11-11 00:00:00 |
2011-11-20 00:00:00 |
Crossed phone line. Local technician working on the problem. |
Local contact fixed crossed phone line. |
149 |
bbd |
Communication - Phone |
2011-10-18 22:00:00 |
2011-11-10 00:00:00 |
Modem does not output tone. Possibly cause is phone network performing upgrade. NIST phone engineers troubleshooting the problem. |
According to NIST telecom, the Long Distance carrier made some adjustments to the trunks. Issue should be resolved. |
145 |
bbd |
Hardware - Instrument |
2011-09-26 15:00:00 |
2011-11-01 00:00:00 |
Net Radiometer reporting false readings. Removed from display. Will replace on next site visit. Approx late Oct early Nov. |
Replaced Net Radiometer |
92 |
bbd |
Communication - Phone |
2011-05-08 22:00:00 |
2011-05-09 13:00:00 |
Hung modem in laboratory modem pool. |
Modem hardware reset. Data backfilled. |
79 |
bbd |
Communication - Phone |
2011-03-27 12:00:00 |
2011-03-30 00:00:00 |
Modem unresponsive. Could be a power failure, modem issue, phone line issue, or comms computer issue. |
Modem connection restored. Snow/Ice build up likely cause for outage. |
69 |
bbd |
Hardware - Instrument |
2011-03-19 14:00:00 |
2011-04-14 22:00:00 |
Snow-depth sensor is buried in the snow. Last reliable reading was 103 inches measured on 3-19-11. |
Snow depth reporting realistic snow depths. Snow pack likely melted lower than snow depth sensor. |