Pine Flat Dam, CA

      Site ID:     pfd
      Latitude:     36.830100 N
      Longitude:     -119.332400 W
      Elevation:     184 meters
      Active:     Y
      Site Table:     Site Table
      Data:     Realtime Display

Instrument Name     Project Name     Install Date     Data Types
Temp/RH - HygroVUE 10     Hydrometeorology Testbed - West     2024-03-21          view
FMCW Precipitation Profiler Digital     Hydrometeorology Testbed - West     2010-12-06          view
Pressure - PTB110B     Hydrometeorology Testbed - West     2010-12-06          view
Datalogger CR800     Hydrometeorology Testbed - West     2010-12-02          view
Tipping Bucket TE525     Hydrometeorology Testbed - West     2010-12-02          view
GpsTrimble NetRS     Hydrometeorology Testbed - West     2010-12-02          view

Instrument Name     Project Name     Install Date     Removal Date     Data Types
Temp/RH CS215     Hydrometeorology Testbed - West     2010-12-02     2024-03-21          view

  OutageID     SiteID     Failure Type     Start Date      End Date      Description     Resolution Description  
809 pfd Hardware - Instrument 2022-04-13 19:30:00 2022-09-08 18:00:00 Possible A/D converter board failure; air conditioner failure Transmitter USB connection changed to a different port on computer; air conditioner replaced
735 pfd Power Failure 2020-08-19 07:00:00 2020-08-22 20:00:00 Can't connect to UPS; possible power outage Power restored
644 pfd Power Failure 2019-08-02 05:30:00 2019-08-02 23:45:00 Unable to reach cellular router. Issue resolved without intervention.
591 pfd Communication - Cellular 2018-05-06 23:45:00 2018-05-07 01:30:00 Can't reach router. Service restored.
588 pfd Communication - Cellular 2018-04-30 14:00:00 2018-05-01 02:30:00 Can't reach router. Service restored.
582 pfd Communication - Phone 2018-02-23 17:00:00 2018-03-15 15:00:00 Can't connect to datalogger. Datalogger restarted.
574 pfd Communication - Cellular 2018-01-10 03:00:00 2018-01-15 18:00:00 Router unreachable. Cellular antenna was disconnected from router port.
553 pfd Hardware - Instrument 2017-09-08 18:00:00 2018-01-10 16:00:00 Datalogger communication interface issue. Intermittent connectivity. Datalogger-PC connection bypassed; datalogger connected directly to router serial port.
523 pfd Communication - Cellular 2017-04-03 06:00:00 2017-04-09 20:00:00 Router failure. Router replaced.
450 pfd Hardware - PC 2015-04-28 02:00:00 2015-09-29 00:00:00 Unable to talk to PC. Router okay. Update 5/4/15. Contact reported blank computer screen after PC bootup. May need to replace Radar PC. Replaced radar PC.
395 pfd Hardware - PC 2014-07-27 00:00:00 2014-08-13 00:00:00 Can reach router okay and can ping PC from router. VNC and SSH unresponsive. Best guess computer tried to reboot and and is in a hung state. Will need to manually restart PC. This is second time this happened withing a week. Need to investigate cause. Radar logs reporting errors of stopping and restarting every hour. Stopped radar. Replaced AC as machine was turning itself off due to extreme heat.
393 pfd Hardware - PC 2014-07-07 00:00:00 2014-07-21 00:00:00 Can reach router okay and can ping PC from router. VNC and SSH unresponsive. Best guess computer tried to reboot and and is in a hung state. Will need to manually restart PC. Contact rebooted machine.
371 pfd Communication - Cellular 2014-03-20 16:45:00 2014-03-24 21:15:00 Router unreachable. Possible power outage. Power restored.
310 pfd Hardware - Instrument 2013-04-26 16:00:00 2013-07-19 00:00:00 GSD reported the GPS Trimble moved approx .06 meters. Cause unknown until engineers can visit the site. Update 6/13/13. It was determined cattle entered the fenced area and moved the GPS dish. GPS IWV restored.
265 pfd Hardware - Instrument 2012-09-14 23:00:00 2012-11-01 22:00:00 Problem with radar PC. Unable to locate USB device. Radar currently disabled. All electronics repaired.
232 pfd Hardware - Instrument 2012-06-05 23:00:00 2012-06-15 03:00:00 Equipment damage from fire at site. Replaced power cable running to site. Melted in fire.
142 pfd Communication - Cellular 2011-09-27 20:00:00 2011-09-28 02:00:00 Site IP unreachable. Either problem with ISP, cellular router, or power issue on site. Site IP returned. No intervention.
110 pfd Communication - Cellular 2011-06-16 15:00:00 2011-07-06 00:00:00 Animal chewed through external antennae cable resulting in cellular outage. Cable repaired.