Colfax, CA

      Site ID:     cfx
      Latitude:     39.090900 N
      Longitude:     -120.948300 W
      Elevation:     731 meters
      Active:     Y
      Site Table:     Site Table
      Data:     Realtime Display

Instrument Name     Project Name     Install Date     Data Types
Tipping Bucket TE525     Hydrometeorology Testbed - West     2005-11-21          view
Temp/RH HMP45C     Hydrometeorology Testbed - West     2005-11-21          view
Soil Moisture 10cm     Hydrometeorology Testbed - West     2005-11-21          view
Soil Moisture 15cm     Hydrometeorology Testbed - West     2005-11-21          view
Soil Temperature 10cm     Hydrometeorology Testbed - West     2005-11-21          view
Soil Temperature 15cm     Hydrometeorology Testbed - West     2005-11-21          view
Datalogger CR1000     California Department of Water Resource     2018-05-21          view

Instrument Name     Project Name     Install Date     Removal Date     Data Types
Datalogger CR10X     Hydrometeorology Testbed - West     2005-11-20     2018-05-21          view

  OutageID     SiteID     Failure Type     Start Date      End Date      Description     Resolution Description  
705 cfx Communication - Cellular 2020-03-28 01:54:00 2021-07-01 00:00:00 Unable to connect to cellular modem; suspected serial-server crash requiring on-site firmware upgrade Modem firmware upgraded
685 cfx Communication - Cellular 2020-01-17 15:54:00 2020-02-14 01:23:00 Can't connect to cellular modem; connection refused; possible modem failure Modem firmware updated to version 2.016 to address serial-server crash bug
679 cfx Communication - Cellular 2020-01-11 11:20:00 2020-01-15 20:00:00 Can't connect to cellular modem Modem firmware failure; modem power cycled on site
208 cfx Hardware - Instrument 2012-04-03 06:00:00 2012-04-25 00:00:00 Tipping bucket clogged. Rain gauge data not accurate. Rain looks accurate on event 4/25/12 16z - 4/16/12 16z compared to nearby gauge cfc. Clog must have corrected itself.
182 cfx Hardware - Instrument 2012-01-22 00:00:00 2012-02-02 23:30:00 Tipping Bucket clogged. No reliable precip reporting as of Jan 22, 2012 0z. Tipping bucket full of saw dust debris from tree trimmings around the site. Tipping bucket cleaned and restarted.
54 cfx Communication - Phone 2011-03-08 20:00:00 2011-03-22 21:00:00 Phone line was unplugged at the junction box. Most likely due to construction occurring around this time period. Phone line plugged back into junction box.