Montgomery Creek, CA

      Site ID:     mgc
      Latitude:     40.868180 N
      Longitude:     -121.886360 W
      Elevation:     1067 meters
      Active:     Y
      Site Table:     Site Table
      Data:     Realtime Display

Instrument Name     Project Name     Install Date     Data Types
Datalogger CR800     Hydrometeorology Testbed - West     2014-09-03          view
Temp/RH CS215     Hydrometeorology Testbed - West     2014-09-03          view
Tipping Bucket TE525     Hydrometeorology Testbed - West     2014-09-03          view
Soil Moisture 10cm     Hydrometeorology Testbed - West     2014-09-03          view
Soil Moisture 15cm     Hydrometeorology Testbed - West     2014-09-03          view
Soil Temperature 10cm     Hydrometeorology Testbed - West     2014-09-03          view
Soil Temperature 15cm     Hydrometeorology Testbed - West     2014-09-03          view

Instrument Name     Project Name     Install Date     Removal Date     Data Types
No inactive instruments exist

  OutageID     SiteID     Failure Type     Start Date      End Date      Description     Resolution Description  
901 mgc Communication - Cellular 2024-02-20 04:00:00 2024-02-20 19:00:38 Unable to connect to cellular modem Connection reestablished
895 mgc Hardware - Instrument 2024-02-05 00:00:00 2024-02-05 18:00:00 Depleted battery; 10.1 volts before losing connection Battery voltage restored by solar panel
797 mgc Hardware - Instrument 2022-01-06 00:00:00 2022-01-08 18:00:00 Datalogger battery voltage low Solar panel recharge
684 mgc Hardware - Instrument 2020-01-22 23:00:00 2020-02-29 18:00:00 Can't connect to cellular modem or datalogger; datalogger battery voltage low (last reading: 10.13469 V) Steady operations returned likely due to increased solar radiation and improved battery charging performance
620 mgc Hardware - Instrument 2019-01-29 03:00:00 2019-02-12 19:32:00 Datalogger battery is failing. Communications are lost during the evening hours. Battery replaced.
513 mgc Communication - Cellular 2017-01-02 07:00:00 2017-02-27 23:00:00 Unable to reach cell router. Could be a power/router issue. Router replaced.
506 mgc Communication - Cellular 2016-10-05 18:00:00 2016-10-06 18:00:00 Lost comms to cell modem. May need to do manual reset. Auto modem restarted.
441 mgc Communication - Cellular 2015-02-08 23:58:00 2015-02-11 00:00:00 Battery voltage dropped to nonstaining levels most likely due cloud covering solar cells ability to charge. Battery fully charged
430 mgc Hardware - Instrument 2014-12-03 03:50:00 2014-12-11 23:00:00 Battery voltage dropped to nonstaining levels most likely due cloud covering solar cells ability to charge. Battery replaced