San Luis Reservoir, CA

      Site ID:     slr
      Latitude:     37.061100 N
      Longitude:     -121.066800 W
      Elevation:     81 meters
      Active:     Y
      Site Table:     Site Table
      Data:     Realtime Display

Instrument Name     Project Name     Install Date     Data Types
FMCW Precipitation Profiler Digital     Hydrometeorology Testbed - West     2013-04-02          view
Tipping Bucket TE525     Hydrometeorology Testbed - West     2013-11-20          view
Temp/RH - HygroVUE 10     Hydrometeorology Testbed - West     2024-03-17          view
Datalogger CR800     Hydrometeorology Testbed - West     2024-03-17          view

Instrument Name     Project Name     Install Date     Removal Date     Data Types
Datalogger CR10X     Hydrometeorology Testbed - West     2013-11-20     2024-03-17          view
Temp/RH HMP45C     Hydrometeorology Testbed - West     2013-11-20     2024-03-17          view

  OutageID     SiteID     Failure Type     Start Date      End Date      Description     Resolution Description  
847 slr Hardware - Instrument 2023-02-03 22:45:00 2023-03-14 20:15:00 DAQ board failure USB connections and hub replaced
775 slr Hardware - Air Conditioner 2021-05-28 18:30:00 2021-10-13 18:15:00 Air conditioner (AC) failure; overheated radar electronics and PC powered off until AC unit is replaced AC replaced
631 slr Communication - Cellular 2019-02-26 23:30:00 2019-02-27 11:46:00 Can't reach cellular router. Cellular-service issue suspected. Service restored .
629 slr Communication - Cellular 2019-02-26 05:00:00 2019-02-26 22:15:00 Can't reach cellular router. Cellular-service issue suspected. Service restored.
586 slr Communication - Cellular 2018-04-23 16:00:00 2018-04-24 22:45:00 Can't connect to router. Power restored.
530 slr Hardware - PC 2017-04-21 00:00:00 2017-05-08 12:00:00 Computer issue requiring site visit. Hard disk defragmented.
378 slr Hardware - Instrument 2014-04-05 17:00:00 2014-04-29 00:00:00 Lost comms with datalogger from PC to datalogger serial cable. Replaced faulty rad modem. Datalogger now connected to router.