| Instrument Name |   Project Name |   Install Date |   Data Types |
| Datalogger CR800 |   Hydrometeorology Testbed - West |   2014-08-29 |   view |
| Soil Moisture 10cm |   Hydrometeorology Testbed - West |   2014-08-29 |   view |
| Soil Moisture 15cm |   Hydrometeorology Testbed - West |   2014-08-29 |   view |
| Soil Temperature 10cm |   Hydrometeorology Testbed - West |   2014-08-29 |   view |
| Soil Temperature 15cm |   Hydrometeorology Testbed - West |   2014-08-29 |   view |
| Temp/RH - HygroVUE 10 |   Hydrometeorology Testbed - West |   2024-02-01 |   view |
| Tipping Bucket TE525 |   Hydrometeorology Testbed - West |   2014-08-29 |   view |
| Instrument Name |   Project Name |   Install Date |   Removal Date |   Data Types |
| Temp/RH CS215 |   Hydrometeorology Testbed - West |   2014-08-29 |   2024-02-01 |   view |
| OutageID | SiteID | Failure Type | Start Date | End Date | Description | Resolution Description |
| 477 | bve | Communication - Cellular | 2015-12-27 22:00:00 | 2015-12-29 22:00:00 | Lost comms with router. | comms restored on its own. |
| 425 | bve | Hardware - Instrument | 2014-12-08 01:34:00 | 2014-12-26 18:00:00 | Battery voltage dropped to nonstaining levels most likely due cloud covering solar cells ability to charge. | Battery came back. |
| 400 | bve | Hardware - Instrument | 2014-08-28 09:00:00 | 2014-10-02 00:00:00 | Temp sensor failed. To be replaced on next visit in early October. | Temp sensor replaced. |