| Instrument Name |   Project Name |   Install Date |   Data Types |
| Instrument Name |   Project Name |   Install Date |   Removal Date |   Data Types |
| 449 MHz Wind Profiler Digital |   Hydrometeorology Testbed - South East |   2013-06-26 |   2015-11-05 |   view |
| Datalogger CR10X |   Hydrometeorology Testbed - South East |   2013-06-26 |   2015-11-05 |   view |
| Tipping Bucket TE525 |   Hydrometeorology Testbed - South East |   2013-06-26 |   2015-11-05 |   view |
| Pressure - PTB101B |   Hydrometeorology Testbed - South East |   2013-06-26 |   2015-11-05 |   view |
| Temp/RH CS215 |   Hydrometeorology Testbed - South East |   2013-06-26 |   2015-11-05 |   view |
| Wind Speed and Direction 5103 |   Hydrometeorology Testbed - South East |   2013-06-26 |   2015-11-05 |   view |
| Solar Radiation CM3 |   Hydrometeorology Testbed - South East |   2013-06-26 |   2015-11-05 |   view |
| Net Radiation REBS Q7.1 |   Hydrometeorology Testbed - South East |   2013-06-26 |   2015-11-05 |   view |
| GpsTrimble NetRS |   Hydrometeorology Testbed - South East |   2013-06-26 |   2015-11-05 |   view |
| Disdrometer Parsivel Optical |   Hydrometeorology Testbed - South East |   2013-06-26 |   2015-11-05 |   view |
| OutageID | SiteID | Failure Type | Start Date | End Date | Description | Resolution Description |
| 470 | ewn | Communication - Cellular | 2015-11-04 13:00:00 | 2015-11-06 00:00:00 | Unable to reach cell phone modem. Could be a power failure, and/or cell modem issue. | Site removed. |
| 324 | ewn | Hardware - Instrument | 2013-07-08 09:00:00 | 2013-07-08 11:00:00 | Data logger overruns in memory causing missing 2-min averages. Changed config file to decrease the memory usage on the datalogger. |