Kernville, CA

      Site ID:     knv
      Latitude:     35.754200 N
      Longitude:     -118.419500 W
      Elevation:     816 meters
      Active:     Y
      Site Table:     Site Table
      Data:     Realtime Display

Instrument Name     Project Name     Install Date     Data Types
Datalogger CR200     Hydrometeorology Testbed - West     2012-04-25          view
FMCW Precipitation Profiler Digital     Hydrometeorology Testbed - West     2012-01-02          view
GpsTrimble NetR8     Hydrometeorology Testbed - West     2012-01-02          view
Pressure - PTB110B     Hydrometeorology Testbed - West     2012-04-25          view
Temp/RH - HygroVUE 10     Hydrometeorology Testbed - West     2023-12-13          view
Tipping Bucket TE525     Hydrometeorology Testbed - West     2012-04-25          view

Instrument Name     Project Name     Install Date     Removal Date     Data Types
Temp/RH CS215     Hydrometeorology Testbed - West     2012-04-25     2023-12-13          view

  OutageID     SiteID     Failure Type     Start Date      End Date      Description     Resolution Description  
773 knv Hardware - Air Conditioner 2021-05-19 18:45:00 2021-05-26 20:24:00 System remotely shutdown due to overheating enclosure Air conditioner replaced during site visit
768 knv Hardware - Instrument 2021-03-31 03:20:00 2021-05-26 20:24:00 Radar PC can't connect to datalogger Datalogger power supplied by AC-blown circuit breaker. AC replaced and datalogger power moved to instrument circuit.
579 knv Hardware - Instrument 2018-02-02 10:00:00 2018-02-07 15:00:00 Can't connect to Trimble GPS. AC power cable disconnected. Batteries drained. Power cable reconnected.
541 knv Hardware - Instrument 2017-06-20 20:00:00 2017-07-19 02:00:00 A/D board intermittently not recognized by the OS. A/C unit not functioning. High enclosure temperature likely causing problems. A/C, radar electronics, and computer scheduled for replacement in July 2017. A/C replaced.
518 knv Communication - Cellular 2017-03-02 02:00:00 2017-03-21 01:30:00 Remote computer unreachable. Computer issue. Computer replaced.
511 knv Communication - Cellular 2016-11-05 09:00:00 2017-01-12 00:00:00 Lost comms with router. Kernville machine was replaced.
504 knv Hardware - Instrument 2016-10-06 01:00:00 2016-10-14 00:00:00 Kernville powered down due to faulty AC. Will need to replace AC before starting system to prevent equipment damage. AC replaced.
396 knv Hardware - Instrument 2014-07-30 15:00:00 2014-08-12 00:00:00 Kernville shutdown as the AC had failed. It was 107 degrees in the shelter at 8am. AC replaced.