Instrument Name |   Project Name |   Install Date |   Data Types |
Datalogger CR800 |   Hydrometeorology Testbed - West |   2014-10-14 |   view |
Soil Moisture 10cm |   Hydrometeorology Testbed - West |   2014-10-14 |   view |
Soil Moisture 15cm |   Hydrometeorology Testbed - West |   2014-10-14 |   view |
Soil Temperature 10cm |   Hydrometeorology Testbed - West |   2014-10-14 |   view |
Soil Temperature 15cm |   Hydrometeorology Testbed - West |   2014-10-14 |   view |
Temp/RH - HygroVUE 10 |   Hydrometeorology Testbed - West |   2023-12-12 |   view |
Tipping Bucket TE525 |   Hydrometeorology Testbed - West |   2014-10-14 |   view |
Instrument Name |   Project Name |   Install Date |   Removal Date |   Data Types |
Temp/RH CS215 |   Hydrometeorology Testbed - West |   2014-10-14 |   2023-12-12 |   view |
OutageID | SiteID | Failure Type | Start Date | End Date | Description | Resolution Description |
826 | lwd | Communication - Cellular | 2022-09-17 01:00:00 | 2022-12-08 22:00:00 | Cellular modem failure | Cellular modem replaced |
710 | lwd | Hardware - Instrument | 2020-03-26 19:16:00 | 2020-05-05 00:00:00 | 10-cm soil temperature sensor malfunction | Instrument values returned to normal |
526 | lwd | Hardware - Instrument | 2017-02-28 17:30:00 | 2017-04-16 18:00:00 | 15 cm soil temperature probe malfunction. The sensor will be replaced on 4/18/17. | Probes replaced on 4/16/17. |