OutageID |
SiteID |
Failure Type |
Start Date |
End Date |
Description |
Resolution Description |
942 |
ptv |
Power Failure |
2024-12-26 23:58:00 |
|
Battery voltage low; 10.49 volts prior to outage |
|
933 |
ptv |
Hardware - Instrument |
2024-11-25 01:58:00 |
2024-11-26 23:58:00 |
Unable to connect to datalogger. Battery voltage low before outage (10.54 V) |
Battery recharged by increased solar radiation |
888 |
ptv |
Hardware - Instrument |
2023-12-01 17:00:00 |
2024-01-31 18:40:00 |
Intermittent data outages due to deteriorating battery performance |
Battery replaced |
887 |
ptv |
Communication - Cellular |
2023-11-15 20:58:00 |
2023-11-16 18:00:00 |
Unable to connect to cellular modem |
Connection re-established |
678 |
ptv |
Communication - Cellular |
2019-12-18 22:00:00 |
2020-01-21 20:00:00 |
Unable to connect to cellular modem |
Service returned |
706 |
ptv |
Hardware - Instrument |
2019-12-18 22:00:00 |
2021-07-21 17:26:00 |
12-volt battery capacity is low; replacement needed; intermittent communication interruptions during prolonged cloudy periods |
Battery replaced |
462 |
ptv |
Hardware - Instrument |
2015-08-12 20:00:00 |
2015-10-20 00:00:00 |
Temperature probe reporting invalid data. |
Probe replaced. |
433 |
ptv |
Hardware - Instrument |
2014-12-09 21:54:00 |
2014-12-24 00:00:00 |
Battery voltage dropped to nonstaining levels most likely due cloud covering solar cells ability to charge. |
Battery came back. |