Instrument Name |   Project Name |   Install Date |   Data Types |
449 MHz Wind Profiler Digital |   Hydrometeorology Testbed - West |   2016-08-23 |   view |
Datalogger CR800 |   Hydrometeorology Testbed - West |   2016-01-20 |   view |
GpsTrimble NetRS |   Hydrometeorology Testbed - West |   2016-08-23 |   view |
Pressure - PTB110B |   Hydrometeorology Testbed - West |   2016-01-20 |   view |
Radio Acoustic Sounding System |   Hydrometeorology Testbed - West |   2016-08-23 |   view |
Solar Radiation - CMP3 |   Hydrometeorology Testbed - West |   2016-01-20 |   view |
Temp/RH - HygroVUE 10 |   Hydrometeorology Testbed - West |   2023-12-12 |   view |
Tipping Bucket TE525 |   Hydrometeorology Testbed - West |   2016-01-20 |   view |
Wind Speed and Direction 5106-5A |   Hydrometeorology Testbed - West |   2016-01-20 |   view |
Instrument Name |   Project Name |   Install Date |   Removal Date |   Data Types |
Temp/RH CS215 |   Hydrometeorology Testbed - West |   2016-01-20 |   2023-12-11 |   view |
OutageID | SiteID | Failure Type | Start Date | End Date | Description | Resolution Description |
930 | sba | Hardware - PC | 2024-10-16 19:00:00 | Radar computer boot failure | ||
877 | sba | Hardware - PC | 2023-09-13 18:00:00 | 2023-09-29 18:30:00 | PC failed to restart after a UPS restart | System restarted |
766 | sba | Hardware - Instrument | 2021-01-27 00:00:00 | 2021-08-31 00:06:00 | Tipping bucket grossly under-reporting precipitation amounts; begin time of malfunction unknown | Tipping bucket leveled, cleaned and tipped twice (0.508 mm reported) at 00:06 UTC on 2021-08-31 |
649 | sba | Hardware - Air Conditioner | 2019-10-01 18:00:00 | 2019-10-11 18:00:00 | Air conditioner failure; radar will be intermittently operational; replacement likely to occur in 1-2 weeks; | On-site repair. |
634 | sba | Communication - Cellular | 2019-03-06 03:00:00 | 2019-03-06 23:00:00 | Can't reach cellular router. Power outages in the area. Generator requires maintenance and is currently disabled. | Power restored. |
573 | sba | Power Failure | 2018-01-10 23:00:00 | 2018-01-23 17:00:00 | Equipment powered down due to malfunctioning air conditioner and overheating. | AC repaired. |