FailureID SiteID Site Name State Failure Type Start Date End Date Failure Description Resolution Description
965 tbm Table Mountain CO Communication - Cellular 2025-08-04 14:43:00 APN on the data logger modem was changed and the modem can no longer be contacted.
975 stf Starkville MS Hardware - Instrument 2026-01-17 15:30:52 The radar has lost either the I or Q channel and cannot determine the direction of the winds. It has been turned off until repairs can be made.
981 std Shasta Dam CA Hardware - Instrument 2026-04-06 11:59:37 Computer cannot communicate with the datalogger. Likely battery failure.
974 slr San Luis Reservoir CA Hardware - PC 2026-02-18 15:28:57 DAQ board not found error. Multiple restarts and service restarts have not fixed the issue.
972 pts Point Sur CA Power Failure 2025-11-17 16:00:35 UPS reports input voltage of only 37 or 38 volts. The UPS will need to be replaced.
977 pfd Pine Flat Dam CA Hardware - PC 2026-04-08 11:50:18 PC rebooted in a disk boot failure, insert system disk state. The AC also appears to be broken according to UPS temperature sensors.
971 ovl Oroville CA Hardware - Instrument 2025-10-01 09:27:48 Data coming back from the SLR is bad. This could be because the radar electronics are bad or because water has gotten into the dish. The cover on the dish will need to be replaced.
969 ner New Exchequer Dam CA Hardware - Instrument 2025-10-03 17:32:59 Lightning strike damaged UPS. Cell router appears to be unaffected. Cannot tell if other equipment was affected without power.
951 mdt Middletown CA Hardware - Instrument 2025-05-13 13:52:27 Radar transmitter not working
976 acv McKinleyville CA Hardware - Instrument 2026-03-15 15:07:22 Radar 449 transmitter broke.
978 lgs Los Gatos CA Communication - Phone 2026-04-07 11:52:23 Cannot reach computer and site contact confirmed the power is on.
985 knv Kernville CA Hardware - Air Conditioner 2026-06-22 11:12:40 Kernville computer was overheating and shutting down periodically. UPS temperature was reading 95+ degrees multiple days in a row.
982 hld Hopland CA Communication - Cellular 2026-06-12 09:04:45 Lost communication with Hopland data logger. Could be a dead battery or a cell issue
980 fks Forks WA Hardware - Instrument 2026-04-29 11:57:30 Computer cannot communicate with the datalogger.
962 ctd Courtland AL Hardware - PC 2025-08-23 14:37:11 Power appears to be off at the site. POC says they do not hear the air conditioner or RASS running. Update from 10/10/25: Power was on, but computer was down. All computer hardware was re-seated and that fixed it. Network card on the UPS is broken and will need to be replaced or fixed. Update from 11/11/25: The computer went down once again, and cannot be brought back online. Will need to be replaced.
979 czc Cazadero CA Communication - Phone 2025-12-20 11:53:18 Communications have been damaged and are very intermittent. May need a new modem or antenna.
961 bby Bodega Bay CA Hardware - Instrument 2024-07-26 15:59:47 Disdrometer is severely corroded. Stats report a damaged laser from approximately this date. As of 12/20/2025, the disdrometer stopped working entirely.
966 ast Astoria OR Hardware - Instrument 2025-08-06 15:07:59 Computer cannot communicate with the datalogger.
983 and Arnold CA Hardware - Instrument 2026-01-28 09:39:24 The 10cm soil temperature probe is reading unreasonable data. It looks like it is now on the surface and exposed to the sun. This also makes the soil moisture readings unusable.
984 abk Arbuckle AZ Hardware - Instrument 2024-11-05 09:43:46 The tipping bucket has not recorded any precip since this date, even though soil moisture indicates precip events.