Site Status

Site Status (for sites maintained by PSL)
Thursday 2nd of April 2026 6:38:00 UTC

Number of Open Entries: 11

SiteID :    Status :    FailureType :

FailureID SiteID Site Name State Failure Type Start Date End Date Failure Description Resolution Description
966 ast Astoria OR Hardware - Instrument 2025-08-06 15:07:59 Computer cannot communicate with the datalogger.
975 stf Starkville MS Hardware - Instrument 2026-01-17 15:30:52 The radar has lost either the I or Q channel and cannot determine the direction of the winds. It has been turned off until repairs can be made.
965 tbm Table Mountain CO Communication - Cellular 2025-08-04 14:43:00 APN on the data logger modem was changed and the modem can no longer be contacted.
951 mdt Middletown CA Hardware - Instrument 2025-05-13 13:52:27 Radar transmitter not working
961 bby Bodega Bay CA Hardware - Instrument 2024-07-26 15:59:47 Disdrometer is severely corroded. Stats report a damaged laser from approximately this date. As of 12/20/2025, the disdrometer stopped working entirely.
969 ner New Exchequer Dam CA Hardware - Instrument 2025-10-03 17:32:59 Lightning strike damaged UPS. Cell router appears to be unaffected. Cannot tell if other equipment was affected without power.
971 ovl Oroville CA Hardware - Instrument 2025-10-01 09:27:48 Data coming back from the SLR is bad. This could be because the radar electronics are bad or because water has gotten into the dish. The cover on the dish will need to be replaced.
972 pts Point Sur CA Power Failure 2025-11-17 16:00:35 UPS reports input voltage of only 37 or 38 volts. The UPS will need to be replaced.
974 slr San Luis Reservoir CA Hardware - PC 2026-02-18 15:28:57 DAQ board not found error. Multiple restarts and service restarts have not fixed the issue.
976 acv McKinleyville CA Hardware - Instrument 2026-03-15 15:07:22 Radar 449 transmitter broke.
962 ctd Courtland AL Hardware - PC 2025-08-23 14:37:11 Power appears to be off at the site. POC says they do not hear the air conditioner or RASS running. Update from 10/10/25: Power was on, but computer was down. All computer hardware was re-seated and that fixed it. Network card on the UPS is broken and will need to be replaced or fixed. Update from 11/11/25: The computer went down once again, and cannot be brought back online. Will need to be replaced.