Instrument Name |   Project Name |   Install Date |   Data Types |
449 MHz Wind Profiler Digital |   National Weather Service |   2017-09-05 |   view |
Datalogger CR10X |   National Weather Service |   2017-08-31 |   view |
GpsTrimble NetRS |   National Weather Service |   2017-09-01 |   view |
Pressure - PTB101B |   National Weather Service |   2017-08-31 |   view |
Temp/RH HMP45C |   National Weather Service |   2017-08-31 |   view |
Wind Speed and Direction 5103 |   National Weather Service |   2017-08-31 |   view |
Solar Radiation CM3 |   National Weather Service |   2017-08-31 |   view |
Tipping Bucket Heated TE525 |   National Weather Service |   2017-08-31 |   view |
Instrument Name |   Project Name |   Install Date |   Removal Date |   Data Types | No inactive instruments exist |
OutageID | SiteID | Failure Type | Start Date | End Date | Description | Resolution Description |
744 | pvl | Hardware - Instrument | 2020-11-21 10:34:00 | 2020-12-25 20:00:00 | Can't connect to datalogger. Possible data cable or modem issue. | Datalogger data cable repaired |
708 | pvl | Power Failure | 2020-03-30 15:58:00 | 2020-04-15 19:15:00 | Power company performing a site upgrade; estimated down time of 2-4 days | Upgrade completed; power restored |
677 | pvl | Hardware - Instrument | 2019-12-12 22:00:00 | 2020-03-18 23:00:00 | Bad GPS power cable suspected | Cable replaced |
645 | pvl | Power Failure | 2019-08-08 22:30:00 | 2019-08-19 22:00:00 | Power down due to multi-day site maintenance. Restoration planned for 2019-8-13 18:00:00 UTC. | Power restored. |
583 | pvl | Power Failure | 2018-03-30 09:00:00 | 2018-04-03 17:00:00 | Router reachable. PC unreachable. | OS not found on PC. PC restarted. Remote access to UPS enabled with web-card installation. |