OutageID |
SiteID |
Failure Type |
Start Date |
End Date |
Description |
Resolution Description |
779 |
and |
Communication - Cellular |
2021-06-16 17:00:00 |
2021-06-28 01:58:00 |
Unable to connect to cellular modem |
Connection reestablished for unknown reason |
758 |
and |
Communication - Cellular |
2021-02-15 08:00:00 |
2021-04-22 00:58:00 |
Unable to connect to cellular modem |
Connection restored for unknown reason |
757 |
and |
Communication - Cellular |
2021-01-11 22:00:00 |
2021-01-17 00:00:00 |
Unable to connect to cellular modem |
Connection reestablished for unknown reason |
749 |
and |
Hardware - Instrument |
2021-01-05 00:00:00 |
2021-11-17 17:00:00 |
Tipping bucket grossly under-reporting precipitation amounts; begin time of malfunction unknown |
Tipping bucket calibrated and funnel cleared of debris |
736 |
and |
Communication - Cellular |
2020-08-18 06:01:00 |
2020-08-24 00:00:00 |
Can't connect to cellular modem |
Connection restored for unknown reason |
733 |
and |
Communication - Cellular |
2020-08-13 04:00:00 |
2020-08-17 01:00:00 |
Can't connect to cellular modem |
Connection reestablished for unknown reason |
731 |
and |
Communication - Cellular |
2020-07-22 08:00:00 |
2020-07-25 05:00:00 |
Can't connect to cellular modem |
Connection reestablished for unknown reason |
725 |
and |
Communication - Cellular |
2020-06-22 14:58:00 |
2020-06-29 02:00:00 |
Can't connect to cellular modem |
Connection reestablished for unknown reason |
721 |
and |
Communication - Cellular |
2020-05-26 22:00:00 |
2020-06-01 05:00:00 |
Unable to connect to cellular modem |
Connectivity returned for unknown reason |
703 |
and |
Communication - Cellular |
2020-03-22 01:00:00 |
2020-03-30 04:58:00 |
Can't connect to cellular modem; suspected serial-server crash requiring on-site firmware upgrade |
Server reset for unknown reason |
691 |
and |
Communication - Cellular |
2020-02-10 22:00:00 |
2020-02-23 23:58:00 |
Can't connect to cellular modem; suspected serial-server crash requiring on-site firmware upgrade |
Communication re-established for unknown reason |
659 |
and |
Power Failure |
2019-10-27 06:58:00 |
2019-10-30 17:00:00 |
Can't connect to cellular modem |
Power restored |
657 |
and |
Communication - Cellular |
2019-10-23 20:58:00 |
2019-10-24 19:14:00 |
Can't connect to cellular modem. |
Connectivity re-established. No data available in memory to backfill during the outage. |
639 |
and |
Power Failure |
2019-06-20 13:54:00 |
2019-07-18 19:06:00 |
Can't connect to cellular modem; datalogger battery voltage dropped to 8.5 before communication was lost; battery failure likely. |
Power failed to site due to water shorting out the
receptacle. Had to redo the conduit and weather proof box added and installed a GFI receptacle at Dormitory building from where our power feed comes from. Installed new battery in the data logger. |